Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Biomedicines ; 11(11)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-38002041

RESUMO

In dentistry, various animal models are used to evaluate adhesive systems, dental caries and periodontal diseases. Metalloproteinases (MMPs) are enzymes that degrade collagen in the dentin matrix and are categorized in over 20 different classes. Collagenases and gelatinases are intrinsic constituents of the human dentin organic matrix fibrillar network and are the most abundant MMPs in this tissue. Understanding such enzymes' action on dentin is important in the development of approaches that could reduce dentin degradation and provide restorative procedures with extended longevity. This in silico study is based on dentistry's most used animal models and intends to search for the most suitable, evolutionarily close to Homo sapiens. We were able to retrieve 176,077 mammalian MMP sequences from the UniProt database. These sequences were manually curated through a three-step process. After such, the remaining 3178 sequences were aligned in a multifasta file and phylogenetically reconstructed using the maximum likelihood method. Our study inferred that the animal models most evolutionarily related to Homo sapiens were Orcytolagus cuniculus (MMP-1 and MMP-8), Canis lupus (MMP-13), Rattus norvegicus (MMP-2) and Orcytolagus cuniculus (MMP-9). Further research will be needed for the biological validation of our findings.

2.
Odontology ; 110(1): 35-43, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34156565

RESUMO

Dental composites are aesthetic materials widely used in Dentistry for replacing hard dental tissues lost due to caries or traumas. The aim of this study was to fabricate low-shrinkage dental composite charged with nanoclay fillers (montmorillonite Cloisite®-MMT) and evaluate their cytotoxicity and physicomechanical properties. Four dental composites were produced from the same organic matrix: Bis-GMA/TEGDMA (30 wt.%). The filler system was constituted of BaSi, SiO2, and MMT in the following concentrations (wt.%): 93.8/6.2/0, 89.1/5.9/5, 86.7/5.8/7.5, and 84.4/5.6/10 (E0: 0; E5: 5%; E7.5: 7.5%; E10: 10% of MMT nanoclays). The following properties were tested: in vitro cytotoxicity, flexural strength, elastic modulus, volumetric shrinkage, water sorption, water solubility, and hygroscopic expansion. Scanning electron microscopy was used to characterize composites' topography. Data were analyzed by one-way ANOVA and Tukey's HSD post hoc test (p < 0.05). MMT nanoclays did not affect the cytotoxicity. E5 and E7.5 groups showed a significant decrease in polymerization shrinkage while maintained the overall physicomechanical properties. The inclusion of 5 and 7.5 wt.% of MMT nanoclays allowed the fabrication of dental composites with low cytotoxicity and low polymerization shrinkage, without jeopardizing the overall behaviour of their physicomechanical properties (flexural strength, elastic modulus, water sorption, water solubility, and hygroscopic expansion). These aspects suggest that the usage of MMT nanoclays could be an effective strategy to formulate new dental composites with clinical applicability.


Assuntos
Bentonita , Resinas Compostas , Bis-Fenol A-Glicidil Metacrilato , Módulo de Elasticidade , Teste de Materiais , Metacrilatos , Polimerização , Ácidos Polimetacrílicos , Dióxido de Silício , Propriedades de Superfície
3.
Braz Oral Res ; 33: e083, 2019 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-31460609

RESUMO

This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey's Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey's test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn't alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


Assuntos
Bis-Fenol A-Glicidil Metacrilato/química , Cerâmica/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Cimentos de Resina/química , Análise de Variância , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Valores de Referência , Reprodutibilidade dos Testes , Autocura de Resinas Dentárias/métodos , Resistência à Tração
4.
Braz. dent. sci ; 22(3): 378-386, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1009381

RESUMO

Objective: The objective of this study was to evaluate the alteration of the optical properties of bulk fill resin-based composites after two years of simulated toothbrushing. Material and Methods: Three high-viscosity bulk fill resin composites and one conventional sculptable resin composite (control) were analyzed. Five specimens of each resin composite were prepared, and roughness, color, translucency and gloss were evaluated initially and after one and two years of simulated toothbrushing. The specimens were submitted to electric simulated toothbrushing (14600 strokes / 100 g) using a commercially available soft bristle toothbrush and toothpaste slurry in a proportion of 1:2 by weight. The brushing scheme was of 40 cycles per day (2 cycles per second / 280 cycles in a week). The optical properties and the roughness data were analyzed by a multifactor analysis of variance (MANOVA) and a Tukey post hoc test. Results: The baseline and final values of Ra and Sa were submitted to linear regression analyses, all of which were performed at a significance level of 5%. Gloss and roughness presented statistical differences between the resin-time interactions in all composite resins. The gloss (72.5%) and roughness (89.4%) worsened significantly after brushing, but the authors didn't find statistically significant differences when evaluating translucency and color. Conclusion: Based in the results, it could be concluded that the simulated brushing degraded the gloss and roughness of the used high-viscosity bulk fill composites. (AU)


Objetivo: O objetivo deste estudo foi avaliar a alteração das propriedades ópticas de resinas compostas do tipo bulk fill após dois anos de escovação simulada. Material e Métodos: Foram analisadas três resinas compostas do tipo bulk fill de alta viscosidade e uma resina composta convencional (controle). Cinco corpos-deprova de cada resina composta foram preparados e a rugosidade, cor, translucidez e brilho foram avaliados inicialmente e após um e dois anos de escovação simulada. Os espécimes foram submetidos a escovação dental simulada (14.600 golpes / 100 g) utilizando-se escova de dentes de cerdas macias comercialmente disponíveis e uma pasta composta de dentifrício e água na proporção de 1:2 em peso. O esquema de escovação foi de 40 ciclos por dia (2 ciclos por segundo / 280 ciclos por semana). As propriedades ópticas e os dados de rugosidade foram analisados por uma análise de variância multifatorial (MANOVA) e um teste post hoc de Tukey. Resultados: Os valores iniciais e finais de Ra e Sa foram submetidos a análises de regressão linear, todas realizadas ao nível de significância de 5%. O brilho e a rugosidade apresentaram diferenças estatísticas entre as interações resina-tempo em todas as resinas compostas. O brilho (72,5%) e a rugosidade (89,4%) pioraram significativamente após a escovação, mas os autores não encontraram diferenças estatisticamente significativas ao avaliar a translucidez e a cor. Conclusão: Com base nos resultados, pôde-se concluir que a escovação simulada degradou o brilho e a rugosidade das resinas compostas do tipo bulk fill avaliadas. (AU)


Assuntos
Escovação Dentária , Análise de Variância , Resinas Compostas
5.
Braz. oral res. (Online) ; 33: e083, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019613

RESUMO

Abstract This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey's Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey's test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn't alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


Assuntos
Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Cerâmica/química , Bis-Fenol A-Glicidil Metacrilato/química , Cimentos de Resina/química , Valores de Referência , Resistência à Tração , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Autocura de Resinas Dentárias/métodos , Cura Luminosa de Adesivos Dentários/métodos
6.
J Prosthet Dent ; 115(3): 356-62, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26548870

RESUMO

STATEMENT OF PROBLEM: Whether laser-welded (LW) titanium can resist the stress corrosion produced by the combination of fluoride ions and stress in the oral environment is unknown. PURPOSE: The purpose of this in vitro study was to investigate the influence of stress corrosion on the mechanical properties of LW titanium. MATERIAL AND METHODS: Twenty-seven titanium bars (25×2 mm) with a circular cross-section were cut in half and laser-welded, while another 27 nonwelded (NW) bars were used as the control. Thirty bars were submitted to a flexural load of 480 N at 1 Hz and immersed in artificial saliva at pH 6 (S1) or in 1000 ppm fluoride-containing saliva at pH 6.0 (S2) or 2.0 (S3) at room temperature for up to 4000 cycles. After the stress corrosion simulation, the tensile strength and Vickers microhardness were determined (n=5). Twelve LW and NW bars were submitted to the corrosion immersion test media for 51 days (n=2) to determine polarization curves (n=2) in an artificial saliva media. The corroded surface was examined with scanning electron microscopy (SEM). RESULTS: The combination of fluoride and low pH significantly decreased the tensile strength of LW (P<.05). Stress corrosion did not affect the hardness of LW or NW (P>.05). NW bars immersed in S3 exhibited progressive surface dissolution, while LW bars spontaneously fractured at the welded area after 25 days of immersion in the same medium. SEM images demonstrated pitting corrosion without the presence of cracks in both groups immersed in S3. CONCLUSIONS: Stress corrosion caused by acidic fluoride-containing saliva and flexural load cycling decreased the tensile strength and hardness of LW titanium bars.


Assuntos
Corrosão , Teste de Materiais , Estresse Mecânico , Titânio/química , Lasers , Microscopia Eletrônica de Varredura , Saliva Artificial , Propriedades de Superfície
7.
Gen Dent ; 63(3): e36-40, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25945777

RESUMO

The objective of this in vitro study was to compare the microleakage of a flowable low-shrinkage-stress resin composite--in a Class II fatigue-loading design when used as a 4 mm dentin replacement--to a conventionally layered silorane-based resin composite. Eighty standardized 4 mm deep cavities, divided into 4 subgroups, were restored with the 2 tested materials. Half of the restorations were submitted to mechanical loading, and all of the restorations were prepared for microleakage evaluation. The evaluation of the marginal adaptation to dentin was performed with scanning electron microscopy. The results showed that both silorane-based composite groups had higher rates of microleakage in comparison to the low-shrinkage-stress resin composite groups.


Assuntos
Resinas Compostas/normas , Infiltração Dentária/etiologia , Resinas Compostas/uso terapêutico , Cárie Dentária/cirurgia , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Restauração Dentária Permanente/normas , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Resinas de Silorano/normas , Resinas de Silorano/uso terapêutico
8.
Rev. bras. odontol ; 70(2): 142-147, Jul.-Dez. 2013.
Artigo em Português | LILACS | ID: lil-744236

RESUMO

O objetivo deste estudo foi coletar dados científicos para revisão de literatura sobre cimentação de cerâmicas, ressaltando propriedades, técnicas, indicações e contraindicações. O agente cimentante ideal deve apresentar como principais características alta resistência à compressão, tração e cisalhamento, além de selamento marginal adequado, baixa solubilidade aos fluidos bucais e espessura mínima de película. Em relação à técnica, foi observado que diferenças na microestrutura e composição dos sistemas cerâmicos exigem protocolos específicos de preparo da peça cerâmica e da superfície dentária. Atualmente, os tipos de agentes cimentantes disponíveis são: fosfato de zinco, ionômero de vidro convencional e modificado por resina, cimentos resinosos e autoadesivos. A evolução desses materiais ocorre no sentido de melhorar propriedades e simplificar a técnica.


The objective of the study was to collect scientific data to perform a literature review of ceramic cementation, highlighting their properties, techniques, indications and contraindications. An ideal luting agent has to present as main characteristics high compressive strength, tensile and shear, adequate marginal sealing, low solubility to oral fluids and minimal thickness of film. Concerning the technique, it was observed that differences on microstructure and composition on ceramic systems require specific protocols on preparation for the ceramic structure and for the dental element surface. Nowadays, the available luting agents are: zinc phosphate, conventional and modified glass ionomer, resin cements and self adhesive cements. The evolution of these materials occurs to improve properties and to simplify technique.


Assuntos
Cimentação , Cimentos Dentários , Porcelana Dentária
9.
Rev. bras. odontol ; 69(2): 242-245, Jul.-Dez. 2012. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-720350

RESUMO

O objetivo deste trabalho foi analisar a influência do tipo de cimento e do modo de ativação na espessura da linha de cimento de copings metálicos cimentados sobre pilares protéticos. Foram utilizados 6 pilares e 6 cilindros do sistema Cera One cimentados com cimento autoadesivo RelyX U200 (3M ESPE, St. Paul - EUA) e também um cimento de fosfato de zinco (S.S. White Artigos Dentários Ltda. - Rio de Janeiro - RJ - Brasil). Foram cimentados 2 cilindros com fosfato de zinco, 2 cilindros com RelyX fotoativado e 2 não fotoativados sendo levados ao microscópio eletrônico de varredura para mensuração da linha de cimento. A diferença entre os grupos foi pequena e o modo de ativação do cimento autoadesivo interfere pouco na espessura da linha de cimento de copings metálicos cimentados sobre pilares protéticos.


The aim of this study was to analyse the effect of the luting agent and the cure mode on the marginal opening of metal copings luted to implant abutments. To test a self-adhesive resin cement and a zinc phosphate cement, were used 6 abutments and 6 cylinders of the Cera One system. The cylinders were luted 2 with zinc phosphate cement, 2 with resin cement light cured and 2 with resin cement not light cured. Afterwards the cylinders were taken to SEM analysis to calculate the marginal opening. The cure mode has a little effect on the marginal opening of metal copings luted to implant abutments.


Assuntos
Microscopia Eletrônica de Varredura , Cimentação , Cimentos de Resina
10.
RPG rev. pos-grad ; 19(2): 39-45, abr.-jun. 012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-688224

RESUMO

O objetivo deste estudo in vitro foi avaliar a morfologia do esmalte dental perante a ação de agentes clareadores, quantitativamente, por meio da mesuração de rugosidade superficial. As superfícies vestibulares de 20 terceiros molares foram seccionadas em duas partes, posicionadas sobre a resina acrílica incolor e armazenadas em água destilada. As amostras foram analisadas em microscópio óptico para a definição de 15 amostras homogêneas e distribuídas aleatoriamente em três grupos experimentais, cada um contendo cinco delas: Grupo 1 - imersão em água destilada, Grupo 2 - gel peróxido de hidrogênio 35 por cento e Grupo 3 - gel peróxido de hidrogênio a 35 por cento e ativação por luz LED (light emitting diodes). As medições da rugosidade foram realizadas para a comparação entre os grupos foi o teste 1 pareado. Não houve diferença estatisticamente significante nos grupos 1 e 2, sendo o valor de p maior do que 0,05. Entretanto, sob as condições experimentais deste trabalho, a técnica clareadora com ativação por luz resultou em alteração eTsatisticamente significante da rugosidade média do esmalte dental, cujo valor foi de p menor do que 0,05. O tratamento clareador com peróxido de hidrogênio a 35 por cento e com fotoativação causou aumento significativo da rugosidade do esmalte dental humano


Assuntos
Humanos , Esmalte Dentário , Estética Dentária , Peróxido de Hidrogênio , Clareamento Dental
11.
Rev. bras. odontol ; 69(1): 21-24, Jan.-Jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-718019

RESUMO

Este artigo tem como objetivo avaliar as tensões de contração de um compósito geradas pela polimerização em função da área aderida. Cilindros de vidro com 2 mm de diâmetro (G1) ou com 4 mm (G2) foram posicionados nas porções inferior e superior da máquina de testes. A distância dos cilindros de G1 era 2 mm e de G2 1 mm. Em cada grupo, a resina (Fill-Magic - Vigodent) foi inserida e fotoativada entre os cilindros e a t ensão m edida p or 1 5 m inutos ( n = 5 ). Os dados foram analisados pelo teste t-Student (p< 0,05). A maior área de adesão gerou menor tensão de contração para o material testado.


The aim of this study is to evaluate the shrinkage stress generated during polymerization of a composite resin related to the adhesion area. Cylinders of glass with 2 mm in diameter (G1) or 4 mm (G2) were positioned on the upper and lower portions of the testing machine. The distance from the cylinders was 2 mm in G1 and 1 mm in G2. In each group, the resin (Fill-Magic - Vigodent) was inserted and photopolymerized between the cylinders and the stress was measured for 15minutes (n = 5). Data were analyzed by Student t test (p < 0,05). The largest area of adhesion generated lower shrinkage stress to the tested material.


Assuntos
Resinas Compostas , Cura Luminosa de Adesivos Dentários , Polimerização
12.
Rev. dental press estét ; 9(2): 114-120, AbrJun.2012. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-857625

RESUMO

O presente trabalho teve como objetivo relatar um caso clínico de reanatomização estética de ambos os incisivos laterais superiores a fim de possibilitar o tratamento ortodôntico. A paciente,de 14 anos de idade, procurou tratamento ortodôntico na clínica da Universidade do Estado do Rio de Janeiro. Durante o exame clínico, observou-se a presença de um incisivo lateral superior permanente com tamanho atípico (12) e outro conoide mesializado (22), além de vários diastemas entre os dentes anteriores. Assim, foi realizado o encaminhamento à Clínica de Dentística para a reanatomização estética de ambos os dentes, a fim de possibilitar a colagem de braquetes ortodônticos. Restaurações diretas de resina composta foram confeccionadas através da técnica da guia de silicone. Após o procedimento, a paciente pôde realizar o tratamento ortodôntico. Contudo, será novamente encaminhada à clínica de Dentística para realização de fechamento dos diastemas depois da remoção do aparelho ortodôntico, já que a aproximação dentária necessária causaria encurtamento da arcada superior.Muitas vezes, a integração entre Dentística e Ortodontia é fundamental para a obtenção de um resultado satisfatório.


This paper aims to report a case of esthetic reanatomization of both upper lateral incisors in order to allow orthodontic treatment. A 14 year-old patient presented at the State University of Rio de Janeiro clinic for orthodontic treatment. During the clinical exam, it was possible to observe an atypically shaped upper lateral incisor (#12) and a peg-shaped mesially positioned upper lateral incisor (#22),aside from multiple diastemas between upper teeth. She was then referred to the Operative Dentistry clinic for the esthetic reanatomization of both upper lateral incisors, in order to allow the bonding of orthodontic brackets. Direct restorations using composite resin were performed using a silicone guide. After the accomplishment of the restorations, the patient was able to undergo the orthodontic treatment. However, she will return to Operative Dentistry clinic for closing diastemas after the removal of orthodontic brackets, because the dental approximation needed would cause shortening of the upper arch. In many situations,the association between Operative Dentistry and Orthodontics is mandatory for a satisfactory result.


Assuntos
Humanos , Feminino , Adolescente , Resinas Compostas , Restauração Dentária Permanente , Dente/anatomia & histologia , Estética Dentária , Incisivo , Ortodontia
13.
Rev. bras. odontol ; 68(2): 252-255, jul.-dez. 2011. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-857516

RESUMO

A proposta deste estudo é avaliar a resistência à tração diametral após dois tipos de fotoativação e armazenamento.Foram confeccionados 24 espécimesdivididos em quatro grupos: G1- fotoativação convencional armazenado em água destilada; G2- pulso tardioarmazenado em água destilada; G3- convencional armazenado em álcool e G4- pulso tardio armazenado em álcool (n = 6). Os grupos foram armazenados a37º C por 24 horas. O foi realizado a uma velocidade de 1.0 mm/min. Os resultados (G1:130.9, G2:127.6, G3:130.8, G4:110.8 MPa) foram submetidos à análise de variância Anova (p ≥ 0,05) e apontam para uma semelhança estatística. Não foi encontrada diferençana resistência coesiva do compósito nos diferentes métodos de fotoativação e meios de armazenamento.


Assuntos
Resinas Compostas , Fenômenos Físicos , Resistência à Tração
14.
Perionews ; 5(6): 669-675, nov.-dez. 2011. ilus
Artigo em Português | LILACS | ID: lil-688090

RESUMO

0 objetivo do presente estudo foi abordar a erosão dentária (ED) decorrente da doença do refluxo gastroesofágico (DRCE) nas diferentes faixas etárias e sua associação com outras doenças, com particular atenção para diagnóstico, prevenção e potenciais perspectivas de tratamento. A elevada prevalência da DRGE, tanto em adulto quanto em criança, observada nas últimas duas décadas, tem sido responsável por tornar esta afecção um problema de saúde pública. Esta doença pode ainda comprometer sítios extradigestórios, como pulmão e ouvido. Ou estar associada com doenças sistêmicas, tal como a diabetes, desordens alimentares, como a bulimia, ou o consumo abusivo de álcool de forma regular. A associação entre a DRCE e o processo de ED, decorrente da acidificação do meio bucal, fragiliza os tecidos mineralizados acarretando a perda destes tecidos. Cabe ressaltar que a ED não está relacionada com o envolvimento bacteriano. Ela é um processo irreversível, que altera aparência, funcionalidade e pode levar à perda do elemento dentário.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Refluxo Gastroesofágico , Gastroplastia , Saúde Pública , Qualidade de Vida , Erosão Dentária
15.
Gen Dent ; 59(2): e82-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21903514

RESUMO

The objective of this study was to evaluate the effect of storage in deionized water at room temperature, for seven days and six months, on the flexural strength of a repaired photocured microhybrid composite resin, using different surface treatments. After each surface treatment, the adhesive interface was analyzed with a surface roughness tester. The flexural strength of samples from each group was determined by three-point bending in a testing machine at a crosshead speed of 0.5 mm/min with a 50 N load cell. Data were analyzed using ANOVA (p=0.0001) and compared with the Newman-Keuls multiple comparison test. It was verified that flexural strength of the unrepaired specimens, after both seven days and six months, was similar (p>0.05) and was in accordance with ISO specifications (minimum of 50 MPa), with values ranging from 52-63 MPa. The authors concluded that the use of an unfilled resin agent is necessary prior to the repair to increase the adhesive strength. Further, the use of a silane agent prior to use of the unfilled resin agent is unnecessary, since it does not increase the adhesive strength.


Assuntos
Resinas Compostas/química , Colagem Dentária , Materiais Dentários/química , Reparação em Prótese Dentária , Acetona/química , Força Compressiva , Análise do Estresse Dentário/instrumentação , Diamante/química , Módulo de Elasticidade , Humanos , Teste de Materiais , Ácidos Fosfóricos/química , Processos Fotoquímicos , Maleabilidade , Polimerização , Ácidos Polimetacrílicos/química , Silanos/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
16.
Rev. bras. odontol ; 68(1): 8-11, jan.-jun. 2011. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-642764

RESUMO

Analisou-se a rugosidade superficial de uma resina acrílica autopolimerizável submetida a dois métodos de polimento: mecânico e químico, antes e após a imersão em soluções de café, café com açúcar, coca-cola e coca-cola light®. Após o polimento, os espécimes foram divididos em 10 grupos experimentais (n = 5): I - polimento mecânico (pm), II - pm em café, III - pm em café com açúcar, IV - pm em coca-cola®, V - pm em coca-cola light®, VI - polimento químico, (pq), VII - pq em café, VIII - pq em café com açúcar, IX - pq em coca-cola®-, X -pq em coca-cola light®. Após a análise de variância (p = 0,000) e Tukey, concluiu-se que a imersão em café aumentou a rugosidade em ambos os tratamentos, ao contrário da coca-cola®.


Assuntos
Café/efeitos adversos , Polimento Dentário/métodos , Bebidas Gaseificadas , Resinas Acrílicas
17.
Rev. bras. odontol ; 68(1): 64-67, jan.-jun. 2011. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-642776

RESUMO

O objetivo deste estudo foi avaliar a resistência à tração diametral de um compósito fotopolimerizável em diferentes temperaturas de armazenamento. Foram confeccionados 12 espécimes cilíndricos (n = 6),que foram divididos em dois grupos: G1- resina à temperatura ambiente (25ºC) e G2- resina utilizada imediatamente após remoção do refrigerador (5ºC). Cada espécime foi confeccionado em três incrementos, cada incremento polimerizado por 40 segundos. Realizouse o teste a uma velocidade de 1.0 mm/min até a falha. Após cada teste, a resistência à tração diametral foi calculada (MPa) e os resultados submetidos à análise estatística, pelo teste t-student (p > 0,05). Não houve efeito da temperatura de armazenamento na resistência coesiva da resina utilizada neste estudo.


Assuntos
Técnicas In Vitro , Resinas Compostas , Temperatura , Teste de Materiais
18.
Rev. flum. odontol ; 15(32): 32-38, jul.-dez. 2009. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-589614

RESUMO

O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos superficiais na rugosidade superficial de uma resina composta microhíbrida fotopolimerizável (TPH Spectrum – Dentsply) armazenada em água deionizada à temperatura ambiente por 7 dias e por 6 meses, associando-os aos resultados do teste de resistência a flexão de reparos. Assim, para cada tempo de envelhecimento, a amostra foi dividida em 5 grupos (n=15), sendo G1, o grupo controle, sem tratamento superficial e os demais: G2 tratamento mecânico com ponta diamantada (no 4138 – KG Sorensen); G3: tratamento com ponta diamantada + condicionamento com ácido fosfórico a 37% (Condicionador Dental Gel – Dentsply); G4: tratamento com ponta diamantada + ácido fosfórico a 37% + adesivo resinoso (Prime & Bond 2.1 – Dentsply) e G5: tratamento com ponta diamantada + ácido fosfórico a 37% + aplicação de silano (Silano Primer e Silano Ativator – Dentsply) + adesivo resinoso. Analisou-se a interface adesiva utilizando-se o rugosímetro, após cada tratamento superficial. Os resultados obtidos mostram que: i) o aumento da rugosidade superficial nos espécimes a serem reparados é desejável, mas não suficiente para promover uma adesão adequada. ii) todavia quando se alia a este procedimento a aplicação de um adesivo resinoso fluido, conjugado ou não com um agente silano, é importante para aumentar a resistência adesiva do material em estudo.


The aim of this study was to evaluate the effect of the different surface treatments on the surface roughness of a micro-hibrid composite (TPH Spectrum – Dentsply) storaged in deionized water at room temperature, for 7 days and 6 months, associated to the flexural strength of repaired ones. For each time of aging, the sample was divided in 5 groups (n=15): G1: control group, unrepaired specimens; G2: mechanical treatment with médium grit diamond bur (4138 – KG Sorensen); G3: diamond bur + etching with 37% phosphoric acid (Dentsply); G4: diamond bur + phosphoric acid etching + unfilled resin (Prime & Bond 2.1 – Dentsply) and G5: diamond bur + phosphoric acid etchning + silane agent (Silano Primer e Silano Ativator – Dentsply) + unfilled resin. After each surface treatment, the adhesive interface was analyzed with a surface roughness tester. According to the results: i) increasing the surface roughness on the speciments to be repaired is desirable but not enough to promote adequate Bond strength, ii) in fact, the use of unfilled resin, combine dor not with silane agent, is important to enhance the flexural Bond strength.


Assuntos
Adesividade , Resinas Compostas , Técnicas In Vitro
19.
Rev. bras. odontol ; 66(2): 152-155, jul.-dez. 2009. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-562656

RESUMO

Avaliou-se a resistência à flexão de três resinas acrílicas autopolimerizáveis (Dencor®, Duralay™, Pattern ™) nas seguintes condições: imediatamente após a manipulação (mif); imerso em água durante 30 dias (ia) e mistura em partes iguais dos polímeros (mp). Formaram-se nove grupos experimentais (n = 10): I Dencor® mif; II Duralay™ mif; III Pattern™ mif; IV Dencor® ia; V Duralay™ ia; VI Pattern™ ia; VII Dencor®- Pattern™ mp; VIII Dencor®- Duralay™ mp e IX Duralay™ e Pattern™ MP. Realizou-se então um ensaio de flexão em três pontos. A resina Pattern™ e a Dencor® apresentaram maior resistência à flexão. Os resultados submetidos à análise de variância apontaram haver diferença entre os grupos (p = 0,000). Os materiais estudados não cumprem as recomendações da ISO 10477/1998.


Assuntos
Teste de Materiais , Fenômenos Físicos , Resinas Acrílicas/normas , Prótese Dentária
20.
Rev. bras. odontol ; 66(2): 202-206, jul.-dez. 2009. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-562666

RESUMO

O objetivo deste trabalho foi comparar a resistência à fratura de próteses parciais fixas provisórias (PPFP) confeccionadas com diferentes materiais. Foram confeccionadas PPFP com os materiais: Dencor, Duralay, Luxatemp, Snap, seguindo as instruções do fabricante (n = 10). Os valores de resistência à fratura foram submetidos à análise de variância e teste de Tuckey (p < 0,05). As médias de resistência à fratura foram (MPa): Dencor 59,16 > Duralay 44,48 > Luxatemp 31,52 = Snap 29,69. As restaurações provisórias confeccionadas com as resinas Dencor e Duralay mostraram-se superiores aos materiais Luxatemp e Snap.


Assuntos
Prótese Parcial Temporária , Teste de Materiais , Fenômenos Físicos , Resinas Acrílicas/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...